• Basic
  • Standard Compliant Channels
  • $50
  • Completely synergize resource taxing relationships via premier market
  • 1 GB of space
  • Support at $25/hour
  • Sign Up
  • Premium
  • Standard Compliant Channels
  • $100
  • Completely synergize resource taxing relationships via premier market
  • 10 GB of space
  • Support at $15/hour
  • Sign Up
  • Platinum
  • Standard Compliant Channels
  • $250
  • Completely synergize resource taxing relationships via premier market
  • 30 GB of space
  • Support at $5/hour
  • Sign Up
Temperature Transmitter Application
Process industry Industrial furnace construction and the thermal industry Plant construction and mechanical engineering Food industry Pharmaceutical industry Cooling systems Heating and air conditioning Plastics industry Renewable energy Water and wastewater
Pressure Transmitter Applications
Monitoring of gaseous, non-aggressive media. Possible usage areas are: • Building automation and air conditioning systems • Overpressure measurement in clean rooms and laboratories • Measurement of constant pressure in VAV applications • Dynamic filter and ventilator monitoring.
Occupancy Sensor Applications
Education, Healthcare, Hospitality, Industrial, Retail

Aerosense Series ADPRHT Clean Room Monitor

Series ADPRHT Clean Room Monitor

Multi-Parameter Display/Transmitter measures Differential Pressure, Humidity, Temperature and optional clock. Series ADPRHT, Multi-parameter display/transmitter measures Differential Pressure, Humidity, Temperature and optional clock. Panel mount/rectangular type cut out for modular wall mounting with stainless steel front plate. Built-in high and low buzzer alarm for process set parameter.

Product Applications:

  • Pharma Cleanrooms, HVAC, Environmental, Pharma machinery, across filters, Hospital isolation room, operation theatres and laboratories.
  • Precision of measurement in HVAC duct pressure application makes this instrument suitable for optimization of energy.
  • Analog output & RS485 communication lead to easy integration with variable frequency drives and SCADA/BMS systems.

Sensor Type:

  • Polymer sensing for Temperature
  • Capacitive polymer sensing for Relative Humidity
  • Piezo Resistive Sensor for Differential Pressure

Range:

  • -30.0 to +50.0 Deg. C typical for Temperature
  • 0.0 to 100.0 % RH typical for Relative humidity
  • 0.0 to +25.0 mm. W.C. / 0 to 250 Pascals (Any other customized range as per user specifications)

Resolution:

  • Fixed 0.1 for both Temperature and Relative humidity 0.1 mm. W.C. or 1 Pascal for Differential Pressure

Accuracy:

  • ±0.5 C for -30 to 50° C for Temperature
  • +/- 1.8% for 10 to 95% RH for Relative humidity
  • +/- 0.5% F.S. for Differential Pressure

Display:

  • 3 Line Red 7 Segment LED Display.
  • 4 Digits for Differential Pressure on Line 1.
  • 4 Digits for % RH. (Humidity) on Line 2.
  • 4 Digits on Temperature (Deg. C) on Line 3.

Display Height Options: -0.4” High Standard, Optional 1” High Display

Differential Pressure Entry: 2 Nos. 4 mm. Hose Nipples at top.

Setting: By 4 keys on the front stainless steel panel.

Buzzer: Integrated buzzer for Alarm in case of process violation of any of the 3 parameters

Supply Voltage: 24VDC , 250mA

Mounting: Wall mounting / Modular Wall Mounting with Stainless Steel Front Flush Plate for Clean Rooms

Sensors: Integrated Humidity & Temperature Sensor flushed to front plate Built in differential pressure sensor with Brass HoseNipples (Chrome Plated) for Differential Pressure At Rear ( 4 mm x 2 Nos.) Optional External Humidity & Temperature Sensor

Communication: RS 485 Modbus Protocol (Optional)

Output: 4-20mA (Optional)

Dimension: Enclosure: 74(W) x 72(H) x 40(D) mm.

Stainless Steel Front Plate: 110W x 90(H) mm

Enclosure: M.S. Power Coated body with Stainless Steel Front Flush Plate for Modular Wall Mounting/Optional Brick Wall Mounting.

Weight: 300 gms. Approx.

Example

ADPRHT

-EX

-15M

-CA

-LED

ADPRHT-EX-15M-CA-LED

Display

Parameters

ADPRHT

       

Differential Pressure/RH & temperature

ARHT

       

Relative Humidity/Temperature

ADPRHTC

       

Differential Pressure/RH & temperature/Clock

ARHTC

       

Relative Humidity/Temperature/Clock

Sensor Location FOR RHT

 

-EX

     

External

-IB

     

Inbuilt

Optional Length of Cable For External Sensor

   

-XXM

   

In Meters (Eg: 15M for 15 Meters)

Optional

Analog

Output/

Communication

     

-A

 

4-20 mA

     

-V

 

0-10 VDC

     

-C

 

RS 485 Modbus Communication

     

-CA

 

4-20 mA & RS 485 Modbus Communication

Display Size

       

-LED

Standard 0.4 Inch Display

         

-1LED

Inch Display

         

-15LED

1.5 Inch Display

         

-2LED

2 Inch Display