Temperature Transmitter Application
Process industry Industrial furnace construction and the thermal industry Plant construction and mechanical engineering Food industry Pharmaceutical industry Cooling systems Heating and air conditioning Plastics industry Renewable energy Water and wastewater
Pressure Transmitter Applications
Monitoring of gaseous, non-aggressive media. Possible usage areas are: • Building automation and air conditioning systems • Overpressure measurement in clean rooms and laboratories • Measurement of constant pressure in VAV applications • Dynamic filter and ventilator monitoring.
Occupancy Sensor Applications
Education, Healthcare, Hospitality, Industrial, Retail

Series DPT-MOD Differential Pressure Transmitter Monitors DP and gives Modbus output

The Series DPT-MOD Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The transmitter for air conforms to MODBUS over serial line protocol, using RTU transmission mode and RS485 interface. The digital output signal is sent over MODBUS enabling the DPT-MOD to connect directly to field communication network. the benefit of DPT-MOD is that it requires less wiring than traditional 3-wire transmitters, since multiple devices can be connected on serial line.

The DPT-MOD includes an Input terminal that enables reading of multiple other signals such as temperature or control relays over MODBUS. The input terminal has two input channels designed to accept 0-10 V, ntc10k, Pt1000, Ni1000 (-LG) and BIN IN (potential free contact) signals.


Product Applications:

  • Fan, Blower and Filter monitoring
  • Pressure and Flow monitoring
  • Valve and damper control
  • Pressure monitoring in cleanrooms

Service: Air and non-aggressive gases

Measuring element: Piezoresistive Accuracy: ±1.5 % + 1 Pa

Measuring unit: Selectable by jumper (Pa, mbar, inchWC, mmWC, psi)

Response Time: 1...20 s selectable via menu

Max pressure: 400 kPa

Electrical interface:

  • Supply voltage: 24 VAC or VDC ± 10%
  • Power consumption: < 1.3 W

Output signal: via Modbus

Materials:

  • Housing: ABS
  • Cover: PC
  • Pressure inlets: ABS

Connections:

  • Electrical connections: 4+3 spring load terminals, max 1.5 mm2
  • Cable entry: M20
  • Pressure connections: Male 5,0 mm and 6,3 mm

Weight: 150 g

Dimensions: 90,0 x 71,5 x 36,0 mm

General ambient condition:

  • Temperature range:
  • Operation -10…+50°C
  • Storage: -20…+70°C
  • Ambient humidity: 0 to 95% RH

Safety:

  • Protection standard: IP54
  • Conformance: Meets the requirements for CE marking:
  • EMC dir ective 2004/108/EY
  • Rohs Directive 2002/95/EY

Optional Accessories:

  • Plastic Pressure Tips
  • 2m Tubes

Model

DPT-MOD-2500

Model

DPT-MOD-7000

-250...2500PA -250...7000PA

Add -D to end of Model with Display For e.g.DPT-MOD-2500-D

TTW series wall mount temperature transmitters are designed for environmental monitoring and controlling in industrial and commercial buildings. These transmitters can be used for indoor air temperature monitoring in various industrial plant, clean room, lab, machine room, office, airport, station, library and stadium etc.

  • Sensor: 10K ^Thermistor Range: 0-50°C Accuracy: -1%
  • 4-2° mA Loop powered models:
  • Power requirements: 24 VDC + 10% Output load: <500^
  • °-1° V Output models:
  • Power requirements: 24 VDCA/AC ±10% Output load: >2K&
  • Optional Display: Aplha numeric LCD Display Resolution: 0.1° C Work Temperature: -40° to 80°C Housing Material: ABS plastic
  • High performance transmitter, ensure accurate temperature measurement.
  • Up to date IC circuit and SMT technology, ensure good long term stability and reliability
  • Fast response

Series

TTW

       

Output

 

1

   

4-2° mA

 

2

   

°-1°VDC

Range

   

S

 

°-5°0 C

   

C

 

Custom Ranges

Display

     

Y

LCD Display

     

N

No Display

TTD/TTI Series Duct Mount temperature transmitters are designed for environmental monitoring and controlling in industrial and commercial buildings. These transmitters can be used for indoor air temperature monitoring in various industrial plant, clean room, lab, machine room, office, airport, station, library and stadium etc.

  • Sensor: 10K^Thermistor/ RTD Range: 0-50°C Accuracy: ±1%
  • 4-20 mA Loop powered models:
  • Power requirements: 24 VDC ± 10% Output load: <500^
  • 0-10 V Output models:
  • Power requirements: 24 VDC/VAC +10% Output load: >2K^
  • Optional Display: Apiha numeric LCD Display Resolution: 0.1°C Work Temperature: -4Cf to 80°C Housing Material: ABS plastic Probe : Material : SS 304 Probe Diameter : 1/4”
  • Probe Length : Refer ordering table
  • High performance transmitter, ensure accurate temperature measurement.
  • Up to date 1C circuit and SMT technology, ensure good long term stability and reliability
  • Fast response



Series

TTD

     

Duct Mount

TTI

     

Immersion Type

Output

 

1

   

4-20 mA

 

2

   

O-10VDC

Range

   

S

 

0-50 C

   

C

 

Custom Ranges

Probe

Length

     

25

2.5”

     

04

4”

     

06

6”

     

08

8”

     

12

12”

Display

     

Y

LCD Display

     

N

No Display

Termowell

Connection

(For TTI Only)

   

110

420

 

PROBE ONLY 1/2”NPT COMPRESSION FITTING 1/4”NPT COMPRESSION FITTING

Series PS Differential Pressure Switch With dual scale field adjustable Set Point Knob

The Series PS Differential Pressure Switch is designed for pressure, vacuum and differential pressure. The dual scaled adjustment knob allows changes to the switching pressure to be made without a pressure gage. The PS is available in settings from 20 Pa to 4500 Pa. The compact size, adjustment knob and low cost make the PS the perfect choice for HVAC applications.

Product Applications:

  • Fan, Blower and filter monitoring
  • Pressure and Flow monitoring
  • Valve and damper monitoring
  • Service: Air & non aggressive gases
  • Material: ABS
  • Electrical Connection: 3 Screw terminal
  • Cable Entry: M16
  • Pressure Connection: Male 0 5 MM
  • Weight: 150 gms
  • Operation Temperature: -20 to 60° C
  • Storage Temperature: -40 to 85° C
  • Maximum Pressure: 50 kPA
  • IP Protection: IP54
  • 2 Fixing Screws
  • 2 Plastic duct connectors
  • 2 m tube 0 4/7 mm
  • Metallic duct connectors

Model Code

Pressure

range

Switching

difference

Accuracy of

Switching

point

Low limit typ.

Electrical

rating

resistive load

Accuracy of

Switching

Point

High limit typ.

Electrical

ratind

inductive load

PS200

20. .200 pa

10 pa

20 Pa±5 Pa

200 Pa±20Pa

01A/250VAC

 

PS300

30.. 300 pa

20 pa

30 Pa±5 Pa

300 Pa±30Pa

3A/250VAC

2A/250VAC

PS500

30. .500 pa

20 pa

30 Pa±5 Pa

500 Pa±30Pa

3A/250VAC

2A/250VAC

PS600

40 .600 pa

30 pa

40 Pa±5 Pa

600 Pa±30Pa

3A/250VAC

2A/250VAC

PS1500

100...1500 pa

80 pa

100 Pa±1OPa

1500 Pa±150Pa

3A/250VAC

2A1250VAC

PS4500

500...4500 pa

180 pa

500 Pa±50 Pa

4500 Pa±200Pa

5A/250VAC

2A/250VAC

Series EDPT Differential Pressure Transmitter

The Series EDPT, Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The compact package is loaded with features such as 2 selectable ranges, 4-20mA output and optional display.

Product Applications:

  • Air Pressure Controller
  • Flow of Air Controller
  • Filter and fan
  • Negative pressure isolation room
  • Engineering machinery and system

  • High Accuracy Sensor
  • Service in Air and non-combustible,Compatible gases.
  • 4 Digital LCD Display
  • Adjustable Zero set point
  • Option of Response Time and Measure Range
  • Light dimension, Easy Set

Model

Measuring Range 1

Measuring Range 2

EDPT100-R2-2W

0-50 PA

0-100 PA

EDPTC100-R2-2W

50-0-50 PA

100-0-100 PA

EDPT250-R2-2W

0-100 PA

0-250 PA

EDPT500-R2-2W

0-250 PA

0-500 PA

EDPT1000-R2-2W

0-500 PA

0-1000 PA

EDPT2500-R2-2W

0-1500 PA

0-2500 PA

EDPT5000-R2-2W

0-2500 PA

0-5000 PA

EDPT05IN-R2-2W

0-0.25” In. WC

0-0.5” In. WC

EDPT5IN-R2-2W

0-2.5” In. WC

0-0.5” In. WC

EDPT10IN-R1-2W

0-10” In. WC

 

EDPT15IN-R1-2W

0-15” In. WC

 

EDPTC05-R2-2W

0.25-0-0.25 In. WC

0.5-0-0.5 In. WC


  • Service: Air and non-aggressive gases
  • Measuring Element: Piezoresistive
  • Accuracy: ±0.8%, or (±1% <100 Pa)
  • Power Requirements: 10~30VDC
  • Output Signal: 4~20mA Max Transfer: 32mA
  • Power Consumption: Supply~10v
  • Material: ABS 0 020A
  • Power Wire: 2 screws max 1.5mm2 , M12 Pressure Wire: Male 5.00mm and 6.3mm Max Pressure: 25kpa
  • Response Time: 0.8/4s
  • Dimension Pressure: 50kpa
  • Temperature Limits: -10~500c
  • Humility: 0~95%RH No LCD
  • Display Weight: 150 Grams With LCD Display
  • Weight: 290 Grams
  • Water Proof: Ip54
  • Approval: CE

Series DPT-R8-3W Differential Pressure Transmitter Monitors Pressure
The Series DPT-R8-3W Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

 

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter condition monitoring

 

Note! Supply voltage must be connected one hour before the 0-point adjustment is carried out.

  • Loose both tubes from the pressure inlets + and -
  • Push zero button until the red led turns ON.
  • Wait until LED turns off and then install tubes again to the pressure inlets.

It is recommended to adjust the zero point every 12 months during normal operation.

If the transmitter is equipped with automatic zero element the manual push button adjustment is not required.

AZ-calibration is a function in the form of an automatic zeroing circuit built into the PCB. The AZ-calibration electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The AZ-calibration eliminates all output signal drift due to thermal, electronic or mechanical effects, as well as the need for technicians to remove high and low pressure tubes when performing initial or periodic transmitter zero point calibration.

The AZ adjustment takes 4 seconds. To avoid conflict with the BAS system, the output and display values will freeze to the latest measured value, after which the device returns to its normal measuring mode. Transmitters equipped with the AZ-calibration are virtually maintenance free.

  • Service: Air and non-aggressive gases Measuring element: Piezoresistive Accuracy: ±0.8%, or (±1% <250 Pa)
  • Measuring unit: Selectable by jumper (Pa, kPa, mbar, inchWC, mmWC, psi)
  • Response Time: 0.8 / 4 s selectable by jumper Max pressure: 400 kPa
  • Electrical interface :
    • Supply voltage: 24 VAC or VDC ± 10 %
    • Power co nsumption: <1.0 W (<1.5W with lout 20mA)
  • Output signal :
    • 0...10 VDC, Load R minimum 1 kQor
    • 4...20 mA, maximum load 500Q
  • Materials:
    • Housing: ABS
    • Cover: PC
    • Pressure connections: ABS
  • Connections:
    • Electrical co nnections: 4 screw terminals, max 1.5 mm2
    • Cable entry: M16
    • Pressure connections: Male 5,0 mm and 6,3 mm Weight: 150 g
  • Dimensions: 90,0 x 71,5 x 36,0 mm
  • General ambient condition:
    • Temperature range:
    • Operation -10...+50°C (-5...+50°C for -AZ model)
    • Storage: -20...+70°C
    • Ambient humidity: 0 to 95% RH
  • Safety:
    • Protection standard: IP54
    • Conformance: Meets the requirements for CE marking:
    • EMC directive 2004/108/EY
    • Rohs Directive 2002/95/EY
  • Optional Accessories:
    • Plastic Pressure Tips
    • 2m Tubes

Model DPT250-R8-3W-D

Model DPT2500-R8-3W-AZ

Model DPT7000-R8-3W-AZ-D

0-25 Pa

100-0-100 Pa

0-1000 Pa

0-50 Pa

0-100 Pa

0-1500 Pa

0-100 Pa

0-250 Pa

0-2000 Pa

0-250 Pa

0-500 Pa

0-2500 Pa

25-0-25Pa

0-1000 Pa

0-3000 Pa

50-0-50 Pa

0-1500 Pa

0-4000 Pa

100-0-100 Pa

0-2000 Pa

0-5000 Pa

150-0-150 Pa

0-2500 Pa

0-7000 Pa

 

Series DPI Differential Pressure Controller

Series DPI electronic pressure measuring devices are engineered for building automation in HVAC/R industry. The most technologically advanced and versatile electronic differential pressure switch combining up to two relay outputs and 0-10V output options.

Optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The AZ adjustment takes
4 seconds. The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects.

Product Application:

  • Fan, Blower and Filter monitoring
  • Staircase pressure monitoring and alarm
  • Pressure monitoring in cleanrooms
  • Boiler pressure monitoring and alarm

AZ-calibration is a function in the form of an automatic zeroing circuit built into the PCB board. The AZ-calibration electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The AZ-calibration eliminates all output signal drift due to thermal, electronic or mechanical effects, as well as the need for technicians to remove high and low pressure tubes when performing initial or periodic transmitter zero point calibration.

The AZ adjustment takes 4 seconds. To avoid conflict with the BAS system, the output and display values will freeze to the latest measured value, after which the device returns to its normal measuring mode. Transmitters equipped with the AZ-calibration are virtually maintenance free.

When the AZ-calibration option is not selected, the product is provided with a manual pushbutton autozero. To maintain proper functionality and accuracy of the transmitter, it is recommended that the manual pushbutton autozero point calibration is performed annually, at a minimum.

  • Service: Dry air or non-aggressive gases
  • Measuring units: PA, kPA, MM WC, IN. WC, mBar selectable via menu Measuring element: Piezo resistive Operating Temperature:
  • Without autozero: -10...50 °C With autozero: -5...50 °C Storage temperature: -20...70 °C Humidity: 0 to 95 % RH, non-condensing Accuracy: ±0.5 % F.S.
  • Long term stability: Typical 1 year With autozero: ±1 Pa Without autozero: ±8 Pa Overpressure:
  • Proof pressure: 25 kPA Burst pressure: 30 kPA
  • Zero point calibration: Automatic with autozero (-AZ) circuit or Manual via menu
  • Response time: 0.5/10 s, selectable via menu Dimensions: 89 x 86.5 x 37.1 mm Weight: 150 g Materials: ABS Protection standard: IP54
  • Touch sensitive buttons on the lid: Menu, Back, OK, down arrow, up arrow
  • Display: 3 1/2 digit LCD backlit display Size: 46.0 W x 14.5 H mm Electrical connections:
  • V out: Terminal block (24 V, GND, 0-10 V)
  • Wire: 12-24 AWG (0.2-1.5 mm2)
  • Relay 1: Terminal block (NC, COM, NO)
  • Wire: 12-24 AWG (0.2-1.5 mm2)
  • Relay 2: Terminal block (NC, COM, NO)
  • Wire: 12-24 AWG (0.2-1.5 mm2)
  • Cable entries:
  • Strain relief: M16 & M20 Knockout: 16 mm Knockout: 20 mm
  • Pressure fittings: 5.2 mm barbed brass Circuit: 3-wire (24 V, GND, 0-10 V)
  • Input:
    • Without autozero: 21-35 VDC/ 24 VAC, ±10 %
    • With autozero: 24 VAC or VDC, ±10 %
  • Output:
    • Analog: 0-10 VDC, Relay 1: 250 VAC / 30 VDC / 6 A Relay 2: 250 VAC / 30 VDC / 6 A Resistance minimum: 1 kQ
    • Current consumption: 35 mA + relays (7 mA each) + AZ circuit (20 mA)

Add -AZ for models with Auto-Zero Feature. + 0^0 v output (10 mA)

For E.g.: DPI2500-2R-AZ-D Conformance: Meets requirements for CE marking

Model Selection Table:

Model

Field Selectable Measuring Range using menu

DPI2500-2R-D

100 / 250 / 1000 / 2500 PA

DPIC500-2R-D

±100 Pa / ±250 / ±300 / ±500 PA

Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure.

Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure - either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication
  • Service: Air and non-combustible, compatible gases (natural gas option available). Wetted Materials: Consult factory
  • Housing: Die cast aluminum case and bezel with acrylic over(MP model has polycarbinate cover)
  • Accuracy: ±2% of full scale (±3%on -0,-100 Pa,-125 Pa.l0MM and ±4% on -00, -60 Pa, -6MM ranges), throughout range at 70‘F (21.1‘C).
  • Pressure Limits:-20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
  • Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicon for diaphragm.
  • Temperature Limits: 20 to 140“F*(-6.67 to 60'C).*low Temperature models available as special option.
  • Size: 4" (101.6 mm) diameter dial face.
  • Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
  • Process Connections: 1/8" female NPT duplicate high and low pressure taps • one pair back.
  • Weight: 1 lb 2 oz (510 g), MP 6 HP 2 lb 2 oz (963 g).
  • Note: May be used with hydrogen when ordering Buna-N diaphragm. Pressure must be less than 35 psi.

Model

Range Inches

Of Water

 Model  Range PSI Model   Range MM of Water  Model  Range kPa

ASG-00+--

ASG-O+-

ASG-Ol

ASG-02

ASG-03

ASG-04

ASG-05

ASG06

ASG-07

ASG-08

ASG-10

ASG-12

ASG-15

ASG-20

ASG-25

ASG-30

ASG-40

ASG-50

ASG-60

ASG-80

ASG-100

ASG-120

ASG-150

ASG-180

ASG-250

0-.25

0-.50

0-1.0

0-2.0

0-3.0

0-4.0

0-5.0

0-6.0

0-7.0

0-8.0

0-10

0-12

0-15

0-20

0-25

0-30

0-40

0-50

0-60

0-80

0-100

0-120

0-150

0-180

0-250

ASG-201

ASG-202

ASG-203

ASG-204

ASG-205

ASG-210

ASG-215

ASG-220

ASG-230

0-1

0-2

0-3

0-4

0-5

0-10

0-15

0-20

0-30

ASG-6MM+..

ASG-10MM+.

ASG-15MM

ASG-25MM

ASG-30MM

ASG-50MM

ASG-80MM

ASG-100MM

ASG-125MM

ASG-150MM

ASG-200MM

ASG-250MM

ASG-300MM

0-6

0-10

015

0-25

0-30

0-50

0-80

0-100

0-125

0-150

0-200

0-250

0-300

ASG-0.5KPA

ASG-1KPA

ASG-1.5KPA

ASG-2KPA

ASG-2.5KPA

ASG-3KF*

ASG-4KFW

ASG-5KRA

ASG-8KPA

ASG-10KPA

ASG-15KPA

ASG-20KPA

ASG-25KPA

ASG-30KPA

 0-0.5

0-1

0-1.5

0-2

0-2.5

0-3

0-4

0-5

0-8

0-10

0-15

0-20

0-25

0-30

 Zero Center Ranges   Model  Range

CM of Water

 Zero Center Ranges   Zero Center Ranges 
 

ASGC-00+..

ASGC-0+..

ASGC-Ol

ASGC-02

ASGC-04

ASGC-10

ASGC-20

ASGC-30

 

0.125-0-0.125

25-0-.25

0.5-0.5

l-O-l

2-0-2

5-0-5

10-0-10

15-0-15

 

ASG-15CM

ASG-20CM

ASG-25CM

ASG-50CM

ASG-80CM

ASG-100CM

ASG-150CM

ASG-200CM

ASG-250CM

ASG-300CM

 

0-15

0-20

0-25

0-50

0-80

0-100

0-150

0-200

0-250

0-300

 

ASGC-6MM+..

ASGC-10MM+.

ASGC-20MM+.

 

3-0-3

5-0-5

10-0-10

 

ASGC-1KPA

ASGC-2KPA

ASGC-2.5KPA

ASGC-3KPA

 

.5-0-.5

1-0-1

1.25-0-1.25

1.5-0-1.5

     Zero Center Ranges   Model  Range Pa    
     

ASGC-4CM

ASGC-10CM

ASGC-30CM

 

2-0-2

5-0-5

150-15

 

ASG-60NPA+..

ASG-60PA+..

ASG-100PA*..

ASG-125PA+..

ASG-250PA

ASG-300PA

ASG-500PA

ASG-750PA

ASG-1000PA

 

10-0-50

0-60

0-100

0-125

0-250

0-300

0-500

0-750

0-100X10

   
      

.Accuracy +/-3%

.. Accuracy +/-4%

Zero Center Ranges      
         Model  Range Pa    
         

ASG-60PA+..

ASGC-100PA+.

ASGC-120PA

ASGC-200PA

ASGC-250PA

ASGC-300PA

ASGC-500PA

ASGC-1000PA

 

300-30

500-50

60-0-60

100-0-100

125 0 125

150-0-150

250-0-250

500-0-500

   

 

 

Series ARHT Humidity & Temperature transmitters are designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used for indoor air temperature and humidity monitoring in various industrial plant, clean room, lab, machine room, commercial buildings, airport, and schools. The modbus interface is documented and integrator friendly. They also have transducer outputs for connecting as analog inputs to all popular control systems.


Series

ARHT

   

Mounting

Option

 

D

Duct

S

Space / Wall

O

Outside Air

Display

Option

 

Y

With

Display

N

Without

Display

 

Relative Humidity Range : 0 to 100% RH.

Temprature Range : -30o to 70oC (-22 to 185oF)

Accuracy : RH : 3% of F.S

Temperature : < + 0.5oC @25oC

Hysteresis : + 1%

Output : 4-20mA , 0-10VDC , 0-5VDC For both Parameters with Modbus

Communication port :RTU 19.2/9600 Band.

Power Requirement : 12 to 24 V AC/DC + 10%

Temprature Limit : -30o to 70oC (22o to 158oF)

Response Time : <10s

RH Sensor : Capacitance Polymer

Temperature Sensor : 10 K Q Thermistor

Enclosure : ABS Plastic (Flammability rating UL 94V0 File E194560)

Probe MOC : Stainless Steel.

Enclosure Rating : ARHT-D & ARTH-O : 1P65 ARHT-W : IP30

Display : LCD , Optional 2 Line Alpha-numeric. Temperature units on Display can be switched by push button to oC or oF.

Display Resolution : 0.1oC , 0.1%RH Drift : < + 0.5%RH

Field Replaceable Sensor to avoid re-calibration.

Series ADPRHT Clean Room Monitor

Multi-Parameter Display/Transmitter measures Differential Pressure, Humidity, Temperature and optional clock. Series ADPRHT, Multi-parameter display/transmitter measures Differential Pressure, Humidity, Temperature and optional clock. Panel mount/rectangular type cut out for modular wall mounting with stainless steel front plate. Built-in high and low buzzer alarm for process set parameter.

Product Applications:

  • Pharma Cleanrooms, HVAC, Environmental, Pharma machinery, across filters, Hospital isolation room, operation theatres and laboratories.
  • Precision of measurement in HVAC duct pressure application makes this instrument suitable for optimization of energy.
  • Analog output & RS485 communication lead to easy integration with variable frequency drives and SCADA/BMS systems.

Sensor Type:

  • Polymer sensing for Temperature
  • Capacitive polymer sensing for Relative Humidity
  • Piezo Resistive Sensor for Differential Pressure

Range:

  • -30.0 to +50.0 Deg. C typical for Temperature
  • 0.0 to 100.0 % RH typical for Relative humidity
  • 0.0 to +25.0 mm. W.C. / 0 to 250 Pascals (Any other customized range as per user specifications)

Resolution:

  • Fixed 0.1 for both Temperature and Relative humidity 0.1 mm. W.C. or 1 Pascal for Differential Pressure

Accuracy:

  • ±0.5 C for -30 to 50° C for Temperature
  • +/- 1.8% for 10 to 95% RH for Relative humidity
  • +/- 0.5% F.S. for Differential Pressure

Display:

  • 3 Line Red 7 Segment LED Display.
  • 4 Digits for Differential Pressure on Line 1.
  • 4 Digits for % RH. (Humidity) on Line 2.
  • 4 Digits on Temperature (Deg. C) on Line 3.

Display Height Options: -0.4” High Standard, Optional 1” High Display

Differential Pressure Entry: 2 Nos. 4 mm. Hose Nipples at top.

Setting: By 4 keys on the front stainless steel panel.

Buzzer: Integrated buzzer for Alarm in case of process violation of any of the 3 parameters

Supply Voltage: 24VDC , 250mA

Mounting: Wall mounting / Modular Wall Mounting with Stainless Steel Front Flush Plate for Clean Rooms

Sensors: Integrated Humidity & Temperature Sensor flushed to front plate Built in differential pressure sensor with Brass HoseNipples (Chrome Plated) for Differential Pressure At Rear ( 4 mm x 2 Nos.) Optional External Humidity & Temperature Sensor

Communication: RS 485 Modbus Protocol (Optional)

Output: 4-20mA (Optional)

Dimension: Enclosure: 74(W) x 72(H) x 40(D) mm.

Stainless Steel Front Plate: 110W x 90(H) mm

Enclosure: M.S. Power Coated body with Stainless Steel Front Flush Plate for Modular Wall Mounting/Optional Brick Wall Mounting.

Weight: 300 gms. Approx.

Example

ADPRHT

-EX

-15M

-CA

-LED

ADPRHT-EX-15M-CA-LED

Display

Parameters

ADPRHT

       

Differential Pressure/RH & temperature

ARHT

       

Relative Humidity/Temperature

ADPRHTC

       

Differential Pressure/RH & temperature/Clock

ARHTC

       

Relative Humidity/Temperature/Clock

Sensor Location FOR RHT

 

-EX

     

External

-IB

     

Inbuilt

Optional Length of Cable For External Sensor

   

-XXM

   

In Meters (Eg: 15M for 15 Meters)

Optional

Analog

Output/

Communication

     

-A

 

4-20 mA

     

-V

 

0-10 VDC

     

-C

 

RS 485 Modbus Communication

     

-CA

 

4-20 mA & RS 485 Modbus Communication

Display Size

       

-LED

Standard 0.4 Inch Display

         

-1LED

Inch Display

         

-15LED

1.5 Inch Display

         

-2LED

2 Inch Display