Temperature Transmitter Application
Process industry Industrial furnace construction and the thermal industry Plant construction and mechanical engineering Food industry Pharmaceutical industry Cooling systems Heating and air conditioning Plastics industry Renewable energy Water and wastewater
Pressure Transmitter Applications
Monitoring of gaseous, non-aggressive media. Possible usage areas are: • Building automation and air conditioning systems • Overpressure measurement in clean rooms and laboratories • Measurement of constant pressure in VAV applications • Dynamic filter and ventilator monitoring.
Occupancy Sensor Applications
Education, Healthcare, Hospitality, Industrial, Retail

Series DPT-MOD Differential Pressure Transmitter Monitors DP and gives Modbus output

The Series DPT-MOD Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The transmitter for air conforms to MODBUS over serial line protocol, using RTU transmission mode and RS485 interface. The digital output signal is sent over MODBUS enabling the DPT-MOD to connect directly to field communication network. the benefit of DPT-MOD is that it requires less wiring than traditional 3-wire transmitters, since multiple devices can be connected on serial line.

The DPT-MOD includes an Input terminal that enables reading of multiple other signals such as temperature or control relays over MODBUS. The input terminal has two input channels designed to accept 0-10 V, ntc10k, Pt1000, Ni1000 (-LG) and BIN IN (potential free contact) signals.


Product Applications:

  • Fan, Blower and Filter monitoring
  • Pressure and Flow monitoring
  • Valve and damper control
  • Pressure monitoring in cleanrooms

Service: Air and non-aggressive gases

Measuring element: Piezoresistive Accuracy: ±1.5 % + 1 Pa

Measuring unit: Selectable by jumper (Pa, mbar, inchWC, mmWC, psi)

Response Time: 1...20 s selectable via menu

Max pressure: 400 kPa

Electrical interface:

  • Supply voltage: 24 VAC or VDC ± 10%
  • Power consumption: < 1.3 W

Output signal: via Modbus

Materials:

  • Housing: ABS
  • Cover: PC
  • Pressure inlets: ABS

Connections:

  • Electrical connections: 4+3 spring load terminals, max 1.5 mm2
  • Cable entry: M20
  • Pressure connections: Male 5,0 mm and 6,3 mm

Weight: 150 g

Dimensions: 90,0 x 71,5 x 36,0 mm

General ambient condition:

  • Temperature range:
  • Operation -10…+50°C
  • Storage: -20…+70°C
  • Ambient humidity: 0 to 95% RH

Safety:

  • Protection standard: IP54
  • Conformance: Meets the requirements for CE marking:
  • EMC dir ective 2004/108/EY
  • Rohs Directive 2002/95/EY

Optional Accessories:

  • Plastic Pressure Tips
  • 2m Tubes

Model

DPT-MOD-2500

Model

DPT-MOD-7000

-250...2500PA -250...7000PA

Add -D to end of Model with Display For e.g.DPT-MOD-2500-D

TTW series wall mount temperature transmitters are designed for environmental monitoring and controlling in industrial and commercial buildings. These transmitters can be used for indoor air temperature monitoring in various industrial plant, clean room, lab, machine room, office, airport, station, library and stadium etc.

  • Sensor: 10K ^Thermistor Range: 0-50°C Accuracy: -1%
  • 4-2° mA Loop powered models:
  • Power requirements: 24 VDC + 10% Output load: <500^
  • °-1° V Output models:
  • Power requirements: 24 VDCA/AC ±10% Output load: >2K&
  • Optional Display: Aplha numeric LCD Display Resolution: 0.1° C Work Temperature: -40° to 80°C Housing Material: ABS plastic
  • High performance transmitter, ensure accurate temperature measurement.
  • Up to date IC circuit and SMT technology, ensure good long term stability and reliability
  • Fast response

Series

TTW

       

Output

 

1

   

4-2° mA

 

2

   

°-1°VDC

Range

   

S

 

°-5°0 C

   

C

 

Custom Ranges

Display

     

Y

LCD Display

     

N

No Display

TTD/TTI Series Duct Mount temperature transmitters are designed for environmental monitoring and controlling in industrial and commercial buildings. These transmitters can be used for indoor air temperature monitoring in various industrial plant, clean room, lab, machine room, office, airport, station, library and stadium etc.

  • Sensor: 10K^Thermistor/ RTD Range: 0-50°C Accuracy: ±1%
  • 4-20 mA Loop powered models:
  • Power requirements: 24 VDC ± 10% Output load: <500^
  • 0-10 V Output models:
  • Power requirements: 24 VDC/VAC +10% Output load: >2K^
  • Optional Display: Apiha numeric LCD Display Resolution: 0.1°C Work Temperature: -4Cf to 80°C Housing Material: ABS plastic Probe : Material : SS 304 Probe Diameter : 1/4”
  • Probe Length : Refer ordering table
  • High performance transmitter, ensure accurate temperature measurement.
  • Up to date 1C circuit and SMT technology, ensure good long term stability and reliability
  • Fast response



Series

TTD

     

Duct Mount

TTI

     

Immersion Type

Output

 

1

   

4-20 mA

 

2

   

O-10VDC

Range

   

S

 

0-50 C

   

C

 

Custom Ranges

Probe

Length

     

25

2.5”

     

04

4”

     

06

6”

     

08

8”

     

12

12”

Display

     

Y

LCD Display

     

N

No Display

Termowell

Connection

(For TTI Only)

   

110

420

 

PROBE ONLY 1/2”NPT COMPRESSION FITTING 1/4”NPT COMPRESSION FITTING

Series PS Differential Pressure Switch With dual scale field adjustable Set Point Knob

The Series PS Differential Pressure Switch is designed for pressure, vacuum and differential pressure. The dual scaled adjustment knob allows changes to the switching pressure to be made without a pressure gage. The PS is available in settings from 20 Pa to 4500 Pa. The compact size, adjustment knob and low cost make the PS the perfect choice for HVAC applications.

Product Applications:

  • Fan, Blower and filter monitoring
  • Pressure and Flow monitoring
  • Valve and damper monitoring
  • Service: Air & non aggressive gases
  • Material: ABS
  • Electrical Connection: 3 Screw terminal
  • Cable Entry: M16
  • Pressure Connection: Male 0 5 MM
  • Weight: 150 gms
  • Operation Temperature: -20 to 60° C
  • Storage Temperature: -40 to 85° C
  • Maximum Pressure: 50 kPA
  • IP Protection: IP54
  • 2 Fixing Screws
  • 2 Plastic duct connectors
  • 2 m tube 0 4/7 mm
  • Metallic duct connectors

Model Code

Pressure

range

Switching

difference

Accuracy of

Switching

point

Low limit typ.

Electrical

rating

resistive load

Accuracy of

Switching

Point

High limit typ.

Electrical

ratind

inductive load

PS200

20. .200 pa

10 pa

20 Pa±5 Pa

200 Pa±20Pa

01A/250VAC

 

PS300

30.. 300 pa

20 pa

30 Pa±5 Pa

300 Pa±30Pa

3A/250VAC

2A/250VAC

PS500

30. .500 pa

20 pa

30 Pa±5 Pa

500 Pa±30Pa

3A/250VAC

2A/250VAC

PS600

40 .600 pa

30 pa

40 Pa±5 Pa

600 Pa±30Pa

3A/250VAC

2A/250VAC

PS1500

100...1500 pa

80 pa

100 Pa±1OPa

1500 Pa±150Pa

3A/250VAC

2A1250VAC

PS4500

500...4500 pa

180 pa

500 Pa±50 Pa

4500 Pa±200Pa

5A/250VAC

2A/250VAC

Series EDPT Differential Pressure Transmitter

The Series EDPT, Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The compact package is loaded with features such as 2 selectable ranges, 4-20mA output and optional display.

Product Applications:

  • Air Pressure Controller
  • Flow of Air Controller
  • Filter and fan
  • Negative pressure isolation room
  • Engineering machinery and system

  • High Accuracy Sensor
  • Service in Air and non-combustible,Compatible gases.
  • 4 Digital LCD Display
  • Adjustable Zero set point
  • Option of Response Time and Measure Range
  • Light dimension, Easy Set

Model

Measuring Range 1

Measuring Range 2

EDPT100-R2-2W

0-50 PA

0-100 PA

EDPTC100-R2-2W

50-0-50 PA

100-0-100 PA

EDPT250-R2-2W

0-100 PA

0-250 PA

EDPT500-R2-2W

0-250 PA

0-500 PA

EDPT1000-R2-2W

0-500 PA

0-1000 PA

EDPT2500-R2-2W

0-1500 PA

0-2500 PA

EDPT5000-R2-2W

0-2500 PA

0-5000 PA

EDPT05IN-R2-2W

0-0.25” In. WC

0-0.5” In. WC

EDPT5IN-R2-2W

0-2.5” In. WC

0-0.5” In. WC

EDPT10IN-R1-2W

0-10” In. WC

 

EDPT15IN-R1-2W

0-15” In. WC

 

EDPTC05-R2-2W

0.25-0-0.25 In. WC

0.5-0-0.5 In. WC


  • Service: Air and non-aggressive gases
  • Measuring Element: Piezoresistive
  • Accuracy: ±0.8%, or (±1% <100 Pa)
  • Power Requirements: 10~30VDC
  • Output Signal: 4~20mA Max Transfer: 32mA
  • Power Consumption: Supply~10v
  • Material: ABS 0 020A
  • Power Wire: 2 screws max 1.5mm2 , M12 Pressure Wire: Male 5.00mm and 6.3mm Max Pressure: 25kpa
  • Response Time: 0.8/4s
  • Dimension Pressure: 50kpa
  • Temperature Limits: -10~500c
  • Humility: 0~95%RH No LCD
  • Display Weight: 150 Grams With LCD Display
  • Weight: 290 Grams
  • Water Proof: Ip54
  • Approval: CE

Series DPT-R8-3W Differential Pressure Transmitter Monitors Pressure
The Series DPT-R8-3W Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

 

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter condition monitoring

 

Note! Supply voltage must be connected one hour before the 0-point adjustment is carried out.

  • Loose both tubes from the pressure inlets + and -
  • Push zero button until the red led turns ON.
  • Wait until LED turns off and then install tubes again to the pressure inlets.

It is recommended to adjust the zero point every 12 months during normal operation.

If the transmitter is equipped with automatic zero element the manual push button adjustment is not required.

AZ-calibration is a function in the form of an automatic zeroing circuit built into the PCB. The AZ-calibration electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The AZ-calibration eliminates all output signal drift due to thermal, electronic or mechanical effects, as well as the need for technicians to remove high and low pressure tubes when performing initial or periodic transmitter zero point calibration.

The AZ adjustment takes 4 seconds. To avoid conflict with the BAS system, the output and display values will freeze to the latest measured value, after which the device returns to its normal measuring mode. Transmitters equipped with the AZ-calibration are virtually maintenance free.

  • Service: Air and non-aggressive gases Measuring element: Piezoresistive Accuracy: ±0.8%, or (±1% <250 Pa)
  • Measuring unit: Selectable by jumper (Pa, kPa, mbar, inchWC, mmWC, psi)
  • Response Time: 0.8 / 4 s selectable by jumper Max pressure: 400 kPa
  • Electrical interface :
    • Supply voltage: 24 VAC or VDC ± 10 %
    • Power co nsumption: <1.0 W (<1.5W with lout 20mA)
  • Output signal :
    • 0...10 VDC, Load R minimum 1 kQor
    • 4...20 mA, maximum load 500Q
  • Materials:
    • Housing: ABS
    • Cover: PC
    • Pressure connections: ABS
  • Connections:
    • Electrical co nnections: 4 screw terminals, max 1.5 mm2
    • Cable entry: M16
    • Pressure connections: Male 5,0 mm and 6,3 mm Weight: 150 g
  • Dimensions: 90,0 x 71,5 x 36,0 mm
  • General ambient condition:
    • Temperature range:
    • Operation -10...+50°C (-5...+50°C for -AZ model)
    • Storage: -20...+70°C
    • Ambient humidity: 0 to 95% RH
  • Safety:
    • Protection standard: IP54
    • Conformance: Meets the requirements for CE marking:
    • EMC directive 2004/108/EY
    • Rohs Directive 2002/95/EY
  • Optional Accessories:
    • Plastic Pressure Tips
    • 2m Tubes

Model DPT250-R8-3W-D

Model DPT2500-R8-3W-AZ

Model DPT7000-R8-3W-AZ-D

0-25 Pa

100-0-100 Pa

0-1000 Pa

0-50 Pa

0-100 Pa

0-1500 Pa

0-100 Pa

0-250 Pa

0-2000 Pa

0-250 Pa

0-500 Pa

0-2500 Pa

25-0-25Pa

0-1000 Pa

0-3000 Pa

50-0-50 Pa

0-1500 Pa

0-4000 Pa

100-0-100 Pa

0-2000 Pa

0-5000 Pa

150-0-150 Pa

0-2500 Pa

0-7000 Pa

 

Page 1 of 2