• Basic
  • Standard Compliant Channels
  • $50
  • Completely synergize resource taxing relationships via premier market
  • 1 GB of space
  • Support at $25/hour
  • Sign Up
  • Premium
  • Standard Compliant Channels
  • $100
  • Completely synergize resource taxing relationships via premier market
  • 10 GB of space
  • Support at $15/hour
  • Sign Up
  • Platinum
  • Standard Compliant Channels
  • $250
  • Completely synergize resource taxing relationships via premier market
  • 30 GB of space
  • Support at $5/hour
  • Sign Up
Temperature Transmitter Application
Process industry Industrial furnace construction and the thermal industry Plant construction and mechanical engineering Food industry Pharmaceutical industry Cooling systems Heating and air conditioning Plastics industry Renewable energy Water and wastewater
Pressure Transmitter Applications
Monitoring of gaseous, non-aggressive media. Possible usage areas are: • Building automation and air conditioning systems • Overpressure measurement in clean rooms and laboratories • Measurement of constant pressure in VAV applications • Dynamic filter and ventilator monitoring.
Occupancy Sensor Applications
Education, Healthcare, Hospitality, Industrial, Retail

Aerosense Series CMT-100 Carbon Monoxide Transmitter


Series CMT-100 Carbon Monoxide Transmitter

Series CMT-100, Carbon Monoxide Transmitter designed to detect Carbon Monoxide gas in air with analog and RS-485 MODBUS output. Measurement range is upto 250 ppm and optional 300 ppm is available. It is 3-wired supporting and gives current, voltage and RS-485 MODBUS output.

Product Applications:

  • Garage Ventilation
  • Vehicle maintenance facility.
  • Pre-Calibrated
  • Convenient use with varying voltage application.
  • Easily installed at a low cost when used with exclusive case Semiconductor use to measure CO levels.
  • Provides output signal proportional to CO level Model available to interact with other Devices Optimum for parking lot, tunnel & under Ground places
  • General Performance
  • Operating Temperature: -10 to 50°C
  • Operating Humidity: 10-95% RH (Non-Condensing)
  • Storage Temperature: -30 to 60°C
  • Storage Humidity: 0-95% RH (Non-Condensing)
  • Operating Environment:
    • Residential
    • Commercial spaces
    • CO Measurement
    • Sensing Method
    • Semiconductor
  • Measurement range: 0-250 PPM
  • Coverage Area: 4000 to 6000 sq. ft. typical
  • Accuracy:
    • @23°C, 50% RH
    • 0-100 ppm: +10% FS
    • 100-250 ppm: +10% FS
  • Response Time: Within 5 minutes
  • Warm - up time: 2 hours
  • Electrical Data
  • Power Input: 24VAC
  • Output Signal
  • Voltage Output: 2-10 VDC
  • Current Output: 4-20 mA