Temperature Transmitter Application
Process industry Industrial furnace construction and the thermal industry Plant construction and mechanical engineering Food industry Pharmaceutical industry Cooling systems Heating and air conditioning Plastics industry Renewable energy Water and wastewater
Pressure Transmitter Applications
Monitoring of gaseous, non-aggressive media. Possible usage areas are: • Building automation and air conditioning systems • Overpressure measurement in clean rooms and laboratories • Measurement of constant pressure in VAV applications • Dynamic filter and ventilator monitoring.
Occupancy Sensor Applications
Education, Healthcare, Hospitality, Industrial, Retail

Aerosense Series CDT-100 Carbon Dioxide Transmitter


Series CDT-100 Carbon Dioxide Transmitter

Series CDT-100, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements.

Measurement range upto 10000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.

Product Applications:

  • Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
  • CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
  • Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
  • RS-485 MODBUS output: (4-wired) Modicon MODBUS RTU mode, which follow Modicon Modbus protocol-settable address ID switch
  • Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch
  • Power: 24VDC, AC
  • Size: 123mmX70mmX43mm
  • Operating Temperature: -10 to 60˚C For -CS Models: -40 to 40˚C
  • Operating Humidity range: 0 to 95% RH
  • Storage temperature: -30 to 70˚C
  • Storage temperature for cold storage: -40 to 70˚C
  • Measurement range: 0 to 2000/ 3000/ 5000/ 10000 ppm (Selectable by Jumper)
  • Accuracy: ±30ppm ±3%
  • Response time: 150 seconds
  • Response time for cold storage: 70 seconds
  • Sampling interval: 3 sec
Model No. Specifications
CDT-100 Carbon Dioxide Transmitter
CDT-100-LCD Carbon Dioxide Transmitter with display
CDT-100-CS Carbon Dioxide Transmitter for cold storage
CDT-100-CS-LCD Carbon Dioxide Transmitter for cold storage with display
CDT-100-M

Carbon Dioxide Transmitter with MODBUS Communication

CDT-100-M-LCD

Carbon Dioxide Transmitter with MODBUS Communication & display