Series ADPRHT Clean Room Monitor
Multi-Parameter Display/Transmitter measures Differential Pressure, Humidity, Temperature and optional clock. Series ADPRHT, Multi-parameter display/transmitter measures Differential Pressure, Humidity, Temperature and optional clock. Panel mount/rectangular type cut out for modular wall mounting with stainless steel front plate. Built-in high and low buzzer alarm for process set parameter.
Product Applications:
Sensor Type:
Range:
Resolution:
Accuracy:
Display:
Display Height Options: -0.4” High Standard, Optional 1” High Display
Differential Pressure Entry: 2 Nos. 4 mm. Hose Nipples at top.
Setting: By 4 keys on the front stainless steel panel.
Buzzer: Integrated buzzer for Alarm in case of process violation of any of the 3 parameters
Supply Voltage: 24VDC , 250mA
Mounting: Wall mounting / Modular Wall Mounting with Stainless Steel Front Flush Plate for Clean Rooms
Sensors: Integrated Humidity & Temperature Sensor flushed to front plate Built in differential pressure sensor with Brass HoseNipples (Chrome Plated) for Differential Pressure At Rear ( 4 mm x 2 Nos.) Optional External Humidity & Temperature Sensor
Communication: RS 485 Modbus Protocol (Optional)
Output: 4-20mA (Optional)
Dimension: Enclosure: 74(W) x 72(H) x 40(D) mm.
Stainless Steel Front Plate: 110W x 90(H) mm
Enclosure: M.S. Power Coated body with Stainless Steel Front Flush Plate for Modular Wall Mounting/Optional Brick Wall Mounting.
Weight: 300 gms. Approx.
Example |
ADPRHT |
-EX |
-15M |
-CA |
-LED |
ADPRHT-EX-15M-CA-LED |
Display Parameters |
ADPRHT |
Differential Pressure/RH & temperature |
||||
ARHT |
Relative Humidity/Temperature |
|||||
ADPRHTC |
Differential Pressure/RH & temperature/Clock |
|||||
ARHTC |
Relative Humidity/Temperature/Clock |
|||||
Sensor Location FOR RHT |
-EX |
External |
||||
-IB |
Inbuilt |
|||||
Optional Length of Cable For External Sensor |
-XXM |
In Meters (Eg: 15M for 15 Meters) |
||||
Optional Analog Output/ Communication |
-A |
4-20 mA |
||||
-V |
0-10 VDC |
|||||
-C |
RS 485 Modbus Communication |
|||||
-CA |
4-20 mA & RS 485 Modbus Communication |
|||||
Display Size |
-LED |
Standard 0.4 Inch Display |
||||
-1LED |
Inch Display |
|||||
-15LED |
1.5 Inch Display |
|||||
-2LED |
2 Inch Display |
Series CDT-100-RLY Carbon Dioxide Transmitter
Series CDT-100-RLY, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements.
Measurement range 2000 ppm (5000/10000 ppm) selectable by jumper. It gives analog and Relay output and supports various functions like recalibration function.
Product Applications:
ELECTRICAL DATA
Model No. | Specifications |
CDT-100-RLY | Carbon Dioxide Transmitter with relay output |
CDT-100-RLY-LCD | Carbon Dioxide Transmitter with relay output & display |
Series CDT-300 Carbon Dioxide Transmitter
Series CDT-300, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements.
Measurement range upto 70000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.
Product Applications:
Model No. | Specifications |
CDT-300 | Carbon Dioxide Transmitter |
CDT-300-LCD | Carbon Dioxide Transmitter with display |
Series CDT-100 Carbon Dioxide Transmitter
Series CDT-100, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements.
Measurement range upto 10000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.
Product Applications:
Model No. | Specifications |
CDT-100 | Carbon Dioxide Transmitter |
CDT-100-LCD | Carbon Dioxide Transmitter with display |
CDT-100-CS | Carbon Dioxide Transmitter for cold storage |
CDT-100-CS-LCD | Carbon Dioxide Transmitter for cold storage with display |
CDT-100-M |
Carbon Dioxide Transmitter with MODBUS Communication |
CDT-100-M-LCD |
Carbon Dioxide Transmitter with MODBUS Communication & display |
Series DPT-MOD Differential Pressure Transmitter Monitors DP and gives Modbus output
The Series DPT-MOD Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The transmitter for air conforms to MODBUS over serial line protocol, using RTU transmission mode and RS485 interface. The digital output signal is sent over MODBUS enabling the DPT-MOD to connect directly to field communication network. the benefit of DPT-MOD is that it requires less wiring than traditional 3-wire transmitters, since multiple devices can be connected on serial line.
The DPT-MOD includes an Input terminal that enables reading of multiple other signals such as temperature or control relays over MODBUS. The input terminal has two input channels designed to accept 0-10 V, ntc10k, Pt1000, Ni1000 (-LG) and BIN IN (potential free contact) signals.
Product Applications:
Service: Air and non-aggressive gases
Measuring element: Piezoresistive Accuracy: ±1.5 % + 1 Pa
Measuring unit: Selectable by jumper (Pa, mbar, inchWC, mmWC, psi)
Response Time: 1...20 s selectable via menu
Max pressure: 400 kPa
Electrical interface:
Output signal: via Modbus
Materials:
Connections:
Weight: 150 g
Dimensions: 90,0 x 71,5 x 36,0 mm
General ambient condition:
Safety:
Optional Accessories:
Model DPT-MOD-2500 |
Model DPT-MOD-7000 |
-250...2500PA | -250...7000PA |
Add -D to end of Model with Display For e.g.DPT-MOD-2500-D
TTW series wall mount temperature transmitters are designed for environmental monitoring and controlling in industrial and commercial buildings. These transmitters can be used for indoor air temperature monitoring in various industrial plant, clean room, lab, machine room, office, airport, station, library and stadium etc.
Series |
TTW |
||||
Output |
1 |
4-2° mA |
|||
2 |
°-1°VDC |
||||
Range |
S |
°-5°0 C |
|||
C |
Custom Ranges |
||||
Display |
Y |
LCD Display |
|||
N |
No Display |